The alarm centre registers the status of your commands through different
tones:
Beep = Command accepted
Beep, beep = Action carried out
Bup = Action failed
Eeh, oh (three times) = Alarm
Pip, pip, pip, pip, pip = Reset required
x You can now listen to the “Voice prompts” of the alarm centre on the
phone.
x The “Voice prompts” with special key combinations (see also chapter
on “Remote control
by telephone”) are as follows:
o #0*0 = Deactivate system
The alarm system is deactivated
In the event of an alarm, also: “Reset is required”.
(Enter the following key combination “#1*1”.)
o #0*1 = Activate system
The alarm system is activated
Note:
The alarm system is activated, even if zones of the
type “Normal Alarm” and “Exit Norm.Alm” are still
open. These zones are omitted.
You have forgotten to set your alarm system
at home. This behaviour allows you to set
your alarm remotely, even if some interior
doors are open.
For controlling with the Realtime Monitor of
the downloader, the same behaviour occurs.
o #0*2 = Activate internal system
The alarm system is activated internally
Note:
The alarm system is activated internally, even if none
of the zones has the “Attribute” “Part setting yes” or
if zones of the type “Normal Alarm” and “Exit
Norm.Alm” are still open. All these zones are omitted.
Refer to the note above as well.
o #1*0 = Disable sirens
In the event of an alarm: “An alarm has been
triggered
o #1*1 = Reset system
In the event of an activated system: “The alarm
system is activated
In the event of a deactivated system: “The alarm
system is deactivated
In the event of an internally activated system: “The
alarm system is activated internally
After an alarm (key combination #0*0 is pressed
beforehand): “The alarm system is deactivated
o #3* = Query system
In the event of an activated system: “The alarm
system is activated
In the event of a deactivated system: “The alarm
system is deactivated
In the event of an internally activated system: “The
alarm system is activated internally
In the event of an alarm: “An alarm has been
triggered
Note
In the event of an alarm, first press the “#0*0” key combination for “Deactivate
system” and then the “#1*1” key combination for “Reset system”.