Suitable advertising material
Details from p. 72
Terxon
Brochure
MBRO70006
Terxon wired and hybrid alarm systems
www.abus.com
Always on the Lookout–
Perfect Protection againstBurglary

The Terxon SX has 8 freely programmable zones available for NC detectors and, addi-
tionally, an aggregate sabotage zone. The wiring type is up to you: NC wiring (with-
out resistor combination, sabotage contact at aggregate sabotage/4 wires required)
or DEOL wiring (2k2/4k7 resistor combination/alarm and sabotage contact in series/2
wires required). An individual sabotage zone is reserved for the signal transmitter.
The three transistor outputs with a switching capacity of 500 mA can be aligned to
a denite event. The Terxon SX can be extended with a relay board (8 relays with
1 A switching capacity). 4 control panels in total can be integrated, which can be
connected via a 4 wire bus wiring. Operating is done with code or chip key. Up to 16
user codes can be dened.
•Comfortable operating via LCD
control panel
•Option of extension with
insertable relay module
•Compact housing
•High security thanks to sabotage
monitored alarm panel, control
panel and detectors