When a detector triggers, it always sends a signal to the alarm system. For
example: A motion sensor reacts to movement, a smoke detector to smoke, etc. So
it is important to tell the system HOW and WHEN it is to react to a signal from a
detector.
Under Zone type, you can program the behaviour of the alarm system when it
receives a signal from a detector. It is absolutely necessary to program this
behaviour since your alarm system will not work without it. The following zone
types are monitored, depending on the state of the alarm system:
1. Disarm: The system reacts to the following zones only: 24-hour, fire, panic and
fault.
2. Arm: The system reacts to all zones.
3. Stay (Internal arm): The system does not react to zones you have programmed
as internal zones. This setting enables you to move within the object when the
perimeter is protected.
There are 22 zone types, whose properties are described in the following:
Under Parameters, press
44
to get to the Zone type menu option. You see the
following on the display:
Enter a two-digit zone number and press
.
Select and configure the zone types as follows:
Zone Type
Quick-Key Menu option Default Selection
22
22
44
ZZZZ
+
0000
Not used
NONE
A
zone programmes as not used is not monitored. The alarm system reacts neither to
battery faults, tampering, nor monitoring failure of the detector trained for this zone.
However, a trained detector is not deleted.
22
22
44
ZZZZ
+
0101
Exit/Entry 1
A
rmed/internal
A
zone programmed as Exit/Entry 1 must not be opened during the exit delay time without
an alarm being triggered. However, the zone must be closed before the exit delay time
expires. If the zone is opened when the alarm system is active, the entry delay time of
Group 1 (to be programmed under System/Timers) is started. The area of the wireless
alarm system must be deactivated in this time. If not, an alarm is triggered following the
expiry of the delay period. Detectors trained for a zone with this property are usually fitted to
front and side doors. This zone must be closed at the moment of activation. If this cannot
always be guaranteed, choose the zone type Exit(OP)/Entry
22
22
44
ZZZZ
+
0202
Exit/Entry 2
A
rmed/internal
See above. However, for zones of this type, the times of Group 2 apply.