The I+Instant zone type is similar to zone type Instant. However, this zone type is not
monitored for an internally activated system.
22
22
44
ZZZZ
+
1111
UO Trigger
rmed
The UO Trigger zone type controls a switch output whether the system is active or inactive.
For example: for temperature sensors that control a ventilator.
22
22
44
ZZZZ
+
1212
Day Zone
rmed
zone with the Day Zone zone type immediately triggers an alarm in an internally or
externally activated system. If the system is inactive, a fault is displayed on the alarm
system display. The fault message can now control a switch output or be viewed by the
user in the user menu under Troubles. This zone type is mostly used to protect emergency
exits.
22
22
44
ZZZZ
+
1313
24 Hours
Default for zone 3
ll
zone with the 24 Hours zone type triggers an alarm immediately, irrespective of the
state of the alarm system. This zone type is mostly used for passive glass breakage
sensors.
22
22
44
ZZZZ
+
1414
Fire
Default for zone 3
ll
zone with the Fire zone type triggers a fire alarm immediately, irrespective of the state of
the alarm system. This zone type is used for smoke detectors.
NOTE:
Zone 33 cannot be programmed as a fire zone.
22
22
44
ZZZZ
+
1515
Panic
ll
zone with the Panic zone type triggers a panic alarm immediately, irrespective of
the state of the alarm system. This zone type is not intended for panic messages
triggered by remote control. See the key-fob menu.
22
22
44
ZZZZ
+
1616
Special
ll
zone with the Special zone type triggers a medical emergency alarm (not a panic
alarm) immediately, irrespective of the state of the alarm system.
22
22
44
ZZZZ
+
1717
Pulse Keyswitch
zone with the Pulse Keyswitch zone type can be used to activate/deactivate an
area. The state change must be in the form: closed – open (pulse) – closed.