No Telephone Line
The switch output is activated if a break in the telephone line is detected. It is deactivated
after the telephone line fault is removed.
33
11
UOUO
11
0303
Communication Failure
The switch output is activated if no contact to the command centre can be established. It is
deactivated after a successful call is made to the command centre.
33
11
UOUO
11
0404
Trouble Follow
The switch output is activated if a system fault is detected. It is deactivated as soon as the
fault is cleared.
33
11
UOUO
11
0505
Low Battery Follow
The switch output is activated if the battery of the ABUS wireless alarm system has
insufficient reserve capacity and the voltage falls to 7V.
33
11
UOUO
11
0606
AC Loss Follow
The switch output is activated if the power supply of the ABUS wireless alarm system is
interrupted and the programmed period is exceeded.
33
11
UOUO
11
0707
Bell Burglary
The switch output is activated if a burglar alarm is triggered in an area.
33
11
UOUO
11
0808
Scheduler
The switch output is activated if the time set in the scheduler is reached.
33
11
UOUO
11
0909
Chime Follow
The switch output is activated if the door chime is activated.
33
11
UOUO
22
Follow Partition
This menu option lists events for an area.
33
11
UOUO
22
0101
Ready Follow
The switch output is activated if all selected areas are in READY state.
33
11
UOUO
22
0202
Alarm Follow
The switch output is activated if an alarm is triggered in the selected area(s).
33
11
UOUO
22
0303
Arm Follow
The switch output is activated if the selected areas are activated in EXTERNAL or
INTERNAL mode . The switch output is activated immediately, regardless of the
programmed exit delay time.
33
11
UOUO
22
0404
Burglary Follow
The switch output is activated if a burglar alarm is triggered in the selected area(s).
33
11
UOUO
22
0505
Fire Follow
The switch output is activated if a fire alarm is triggered in the selected area(s) or if the
(FIRE) alarm buttons are pressed simultaneously.